Call for Expression of Interest from Qualified Firms for Supply, Installation and After-Sales Service of Clean Heating Solutions
Dhaulagiri Community Resource Development Center (DCRDC) invites Expressions of Interest (EOI) from eligible and qualified private-sector firms for the supply, installation, commissioning and after-sales service of clean heating, electrical upgrade and renewable energy solutions under the HEARTH – Harnessing Renewable Energy for Clean Heating in the Himalaya project in Lower Mustang, Nepal.
The project is funded by the Clean Air Fund, led by ICIMOD, and implemented by Practical Action in collaboration with DCRDC as the local implementing partner. The project aims to support the transition from traditional biomass-based heating to clean, reliable and affordable electric heating solutions, complemented by renewable energy.
The EOI is intended primarily to identify and shortlist qualified suppliers, service providers, contractors and specialist firms with the relevant technical capacity, experience and after-sales support arrangements. The proposed interventions are offered as a single integrated Thermal Package comprising all four components described below. Firms must express interest in, and demonstrate capacity to deliver, the complete package. EOIs covering only part of the package will not be considered.
Detailed technical specifications, quantities, site-specific requirements and pricing will be developed and requested through the subsequent procurement process. Submission of an EOI does not constitute a commitment by DCRDC or the project to purchase any specified quantity or award a contract.
1. Scope of Services – Integrated Thermal Package
The Thermal Package comprises the following three components. Applicants must cover all components, either directly or through documented supplier, manufacturer or subcontractor arrangements, with the lead applicant remaining fully responsible for delivery of the whole package:
Component 1: Household Heating Products
This component primarily covers the supply, delivery, warranty and after-sales support of household electric heating appliances, including:
i. Portable electric space heaters are suitable for household use, with appropriate safety features and specifications as defined by the project in Annex I.
ii. Electric blankets, including associated controls and safety features; Annex I.
iii. Household wiring
1. Electrical wiring and associated accessories upgrades;
2. Replacement or upgrading of sockets, MCB/RCCB, connection point;
3. Earthing and electrical safety improvements;
4. Testing and verification of completed electrical works.
Installation of these appliances is generally not expected under this component, although the firm may be required to provide basic installation guidance or demonstration where necessary.
Component 2: Institutional Heating Systems
This component covers the supply, installation, integration, testing, and commissioning of institutional clean-heating systems. At the EOI stage, firms are not required to propose or submit technical specifications for institutional heating systems; they only need to confirm and demonstrate that they have the capacity to supply, install and commission such systems. The Detailed Feasibility Study (DFS) will be conducted separately, and the relevant findings, technologies, specifications, capacities, and configurations will be provided to the selected firm for implementation.
The scope of work includes:
i. Supply of the specified institutional heating technology and associated equipment, components, and accessories.
ii. Installation and integration of the heating system with the existing building infrastructure and electrical system, as applicable.
iii. Testing, commissioning, and verification of system functionality and performance against the specified requirements.
Potential technologies include air-source heat pumps, electric radiant heating, electric underfloor heating, and other equivalent clean-heating technologies that will be specified in the DFS report.
Component 3: Grid-connected Solar PV Systems
This component covers the integrated supply, installation, testing, commissioning and after-sales service of solar PV systems as specified in Annex I, including, as applicable:
i. Solar PV modules, Grid-connected inverters and associated protection equipment;
ii. Mounting structures and balance-of-system components should be suitable for mud-roof
iii. DC and AC cabling and associated electrical protection;
iv. Metering and net-metering-related requirements, where applicable;
v. Reverse feed control system
vi. System installation, testing and commissioning;
vii. System performance monitoring, verification and documentation; including SIM-based remote monitoring and data transmission,
viii. Household wiring
1. Electrical wiring and associated accessories upgrades;
2. Replacement or upgrading of sockets, MCB/RCCB, connection point;
3. Earthing and electrical safety improvements;
4. Testing and verification of completed electrical works.
The final system capacity, configuration and site-specific requirements will be determined based on the Detailed Feasibility Study (DFS), site assessment and approved technical design for both household and Institutions.
2. Transportation and Site Delivery
For all components of the package, firms must have the capacity to arrange the safe transportation and delivery of equipment, materials and associated components to the designated project locations in Lower Mustang, including coordination of delivery schedules and site access requirements.
3. User Orientation and After-Sales Support
For each component of the package, the selected firm will be expected to provide appropriate user or operator orientation, warranty documentation, basic operation and maintenance guidance, and responsive after-sales support. The specific warranty period, service response requirements and maintenance obligations will be defined in the subsequent procurement documents.
4. Application for the Full Package
Firms must apply for the complete package covering all the components (household heating products, household basic wiring upgrade, institutional heating systems, and grid-connected solar PV systems). Where the applicant does not itself manufacture or install a particular component, it must submit agreements or letters of commitment with the relevant suppliers, manufacturers or subcontractors. The lead applicant will hold sole contractual responsibility for delivery of the entire package.
5. Local Partnership and Service Consideration
The lead applicant shall be a company legally registered in Nepal and willing to work closely with local vendor/shop operating within Gharapjhong Rural Municipality (e.g., Jomsom, Marpha or surrounding areas) to support the supply, installation and after-sales servicing of the proposed clean-heating solutions.
6. Indicative Beneficiary Coverage
The project will support a minimum of 70 households and 5 institutions in Lower Mustang through clean-heating solutions, subject to beneficiary eligibility, technical feasibility, available resources, and subject to the applicable project procedures and verification requirements.
Implementation coverage and sequencing
The project will be implemented in two lots. Following are details of each Lot:
Table: Implementation Coverage and Schedule by Lot
Quantity
Description Lot 1 Lot 2 Total
Households 30 40 70
Institutions 5 5
Date Nov 2026 -Jan 2027 Feb 2027 – May 2027
7. Information to be Submitted
Interested firms are requested to submit an EOI containing the following information:
i. Company Profile
o Company Details including registration details; PAN/VAT details; latest tax clearance certificate.
o Contact details; Name and designation of authorized contact person.
ii. Relevant Experience across the package components
o Description of similar assignments; Experience in remote/high-altitude locations,
o Project/supply proof of working in remote area of minimum 100 sites
o Relevant client/project references from at least 2 customers
iii. Technical Capacity
o Turnover in the last 3 years and cash positive
o Details of technical and installation personnel at least 5;
o Installation and service capacity; and
o Proposed approach for servicing Lower Mustang.
iv. Proposed Product Portfolio
o Product/manufacturer details including model and technical specifications for household heaters, electric blankets, wiring materials and solar PV systems;
o Applicable certification/standards;
o Warranty period; and Product catalogues/brochures.
o For institutional heating systems, no product specifications are required at the EOI stage; a brief statement of capacity to supply, install and commission such systems (with any relevant past examples) is sufficient.
v. Partner Details
o Agreements or letters of commitment with suppliers/manufacturers/subcontractors (solar PV, heaters, institutional heating technology) for any component not delivered directly by the applicant;
o Name and registration details of the proposed local partner;
o Address and location of service center in Gandaki Province;
o Technical/service capacity;
o Copy of the participation/partnership agreement or formal letter of commitment between the applicant and local partner.
vi. After-Sales Service Plan
o Warranty arrangements;
o Service and response mechanism;
o Spare-parts availability;
o Repair and replacement arrangements;
vii. Commercial Information
o Indicative per-unit cost for household heaters, electric blankets, household wiring upgrade and household solar PV system (not required for institutional heating systems, which will be priced after the DFS).
8. EOI evaluation/shortlisting criteria
The submitted EOIs will be reviewed to identify firms that demonstrate the relevant technical capacity, experience, financial and operational capability, and ability to provide reliable services across all components of the Thermal Package. Only EOIs covering the full package will be evaluated.
The evaluation will be undertaken based on the information submitted in the EOI and may include verification of the information provided. The indicative shortlisting criteria are as follows:
S.N. Evaluation Criteria Key Areas of Assessment
1 Legal Status and Eligibility Valid registration of the company/firm; relevant business license/registration; tax registration and compliance; eligibility to undertake the proposed supply or service. Provide tax clearance of FY 82/83.
2 Relevant Experience Demonstrated more than 3 years of experience in supplying, installing or servicing products/systems relevant to the package components; number of similar assignments completed.
3 Technical Capacity Availability of qualified technical personnel, engineers, electricians, installers or other relevant specialists; capacity to undertake design, installation, testing and commissioning where applicable.
4 Product/Technology Capability Availability and suitability of proposed products/technologies for household heating, wiring and solar PV; compliance with applicable national/international standards and safety requirements; ability to provide technical documentation, manuals and warranty certificates. For institutional heating systems, assessment will be based on demonstrated capacity to supply and install, not on product specifications.
5 Supply and Logistics Capacity Ability to procure, transport and deliver equipment and materials to Project site; availability of supply channels, stock or manufacturer/supplier arrangements;
6 Installation and Commissioning Capacity Where applicable, demonstrated capacity for installation, testing, commissioning, system integration and performance verification. This will be particularly relevant for solar PV and institutional heating systems.
7 Integrated Package Delivery Capacity Ability to provide complete supply, installation, testing, commissioning and after-sales services across all four components of the package, directly or through documented supplier/subcontractor arrangements under a single lead applicant.
8 Warranty and After-Sales Service Warranty arrangements, availability of spare parts, repair and replacement arrangements, technical support, maintenance services and expected response time.
9 Relevant Local/Regional Presence Availability of service personnel, technicians, authorized representatives or established service arrangements, ability to provide support in Mustang.
10 Financial and Operational Capacity Demonstrated capacity to undertake the anticipated scale of supply/service, including appropriate organizational resources and financial capacity.
9. Submission of EOI
Interested and eligible firms are requested to submit their EOI electronically to:
Dhaulagiri Community Resource Development Centre (DCRDC)
Email: dcrdc.ntc.net.np
Subject: EOI – Supply, Installation and After-Sales Service of Clean Heating Solutions under HEARTH
Deadline for Submission: 26 November 2026
For further information:
DCRDC
Baglung Municipality-4, Baglung Nepal
Email: – [email protected]
Website: www.dcrdc.org.np
Annex I:
Technical Specification – Electric Space heaters for Households
S.N. Parameter Minimum RFQ Requirement
1 Type Electric room/space heater with fan assist suitable for indoor heating listed below:
– Oil filled radiator
– Positive Temperature Coefficient (PTC)/ Ceramic heater
2 Rated Heating Capacity Minimum 2,000 W (2.0 kW)
3 Rated Voltage 220–240 V AC, single phase
4 Frequency 50 Hz
5 Power/Heat Settings Minimum 2 selectable settings, to allow adjustment of heat output
7 Overheat Protection Automatic overheat protection and thermal cut-out
8 Display & Controls Clear display and simple, user-friendly controls
9 Electrical Cable & Plug Factory-fitted cable and plug suitably rated for the maximum load and compatible with 230 V, 50 Hz supply; minimum 16 A rating.
10 Safety Heating element adequately guarded; housing and components suitable for high-temperature operation
11
Operating Environment Suitable for indoor operation in cold, high-altitude conditions (approx. 2,500–3,000 masl) of below 0 °C
12 Standards – Nepal Comply with applicable NS 564:2076 – Household and Similar Electrical Appliances – Safety – Part 1: General Requirements, including applicable amendments for safety of household and similar electrical appliances
13 Equivalent Standards Where applicable, comply with
• IS 302 (Part 2/Sec 30):2007 – Safety of Household and Similar Electrical Appliances – Particular Requirements – Room Heaters, including applicable amendments, or
• IEC 60335-2-30 or equivalent latest applicable standard
14 Performance Standard Where applicable, for direct-acting room heaters, IS 369:2019 or equivalent applicable international standard
15 Certification/Compliance Bidder shall provide manufacturer’s test report, certificate, declaration of conformity, or equivalent evidence of compliance with the applicable standard
16 Warranty Minimum 1-year comprehensive warranty covering electrical, heating and control components
17 After-Sales Service Availability of repair/service support and essential spare parts during the warranty period
18 Accessories Supplied complete with power cable, plug, standard accessories, remote control/batteries where applicable, and user manual
19 Product Condition Brand new, unused and current production model; refurbished units not acceptable
Technical Specifications: Electric Blankets
S.N. Parameter Minimum specification
1 Type and size Household electric blanket; single or double bed size as specified
2 Rated voltage/frequency 220–240 V AC, 50 Hz
3 Rated power Approximately 60–120 W (single) or 100–180 W (double), subject to manufacturer specifications
4 Temperature control Adjustable heat settings with at least 3 levels
5 Safety features Built-in thermostat, overheat protection and automatic power cut-off
6 Automatic shut-off Integrated timer, preferably within 12 hours
7 Electrical safety Insulated heating elements, protected wiring and safe, compatible power plug
8 Controller Dedicated ON/OFF and temperature controller; detachable preferred
9 Material and maintenance Durable, skin-safe fabric; washable as per manufacturer instructions
10 Standards Compliance with IEC 60335-2-17 or equivalent applicable safety standards
11 Accessories Controller, power cable, user manual and safety instructions
12 Warranty Minimum 12 months, including after-sales support in Nepal
Household basic wiring upgrade – requirement
– Supply, installation, testing and commissioning of household wiring from the existing meter/distribution board to the designated space-heating area.
– Provide two 16 A, 3-pin earthed power sockets, suitable for 220–240 V AC, 50 Hz.
– Use minimum 2.5 mm² copper wiring, suitably rated protective earth conductor, and quality conduit, boxes and accessories.
– Provide appropriately rated MCB/MCCC/circuit protection, as required.
– Use standard-quality materials and comply with NS 387:2054, where applicable, and other relevant Nepal Standards
Institutions Heating Systems requirement
For institutional applications, the project is considering building-scale, high-efficiency electric heating solutions suitable for the climatic and building conditions of Lower Mustang. At the EOI stage, firms are not required to submit technical specifications or propose a fixed technology or system capacity. Firms only need to state and demonstrate that they have the capacity to supply, install and commission institutional heating systems.
The technologies currently under consideration include:
• Electric radiant floor heating systems, or equivalent systems;
• Ground-source heat pump systems or equivalent systems e.g. Air to air heat pump
• Solar thermal augmented technologies or hybrids
The final technology selection, system capacity, configuration and design will be determined through the Detailed Feasibility Study (DFS).
The selected firm will be expected to implement the technology and system configuration approved by the project based on the findings of the DFS.
Solar PV System (Minimum 1 kWp) – Minimum Specifications
• Minimum 1 kWp solar PV modules with grid-connected inverter compatible with net metering for household
• Institutional Solar PV system to be provided after Detailed feasibility Study.
• Rust-resistant mounting structure with corrosion-resistant fasteners suitable for mud-roof structure in Mustang region
• Proper earthing and lightning protection, as required.
• Compliance with applicable Renewable Energy Test Station (RETS), The Nepal Photovoltaic Quality Assurance (NEPQA), Nepal Standards and other relevant standards.